Product Catalogue
Home > Product Center - LK->Contactor and relay -> CJX2-DN AC Contactor
Rated current | le max AC-3 (Ue≤440V) | 9A | 12A | 18A | 25A | 32A | ||
le AC-1 (0≤60°C) | 25A | 32A | 40A | 50A | ||||
Number of poles | 3 | 3 | 4 | 3 | 3 | 4 | 3 | |
Rated operational power in AC-3 |
220/240V | 2.2KW | 3KW | 4KW | 5.5KW | 7.5KW | ||
380/400V | 4KW | 5.5KW | 7.5KW | 11KW | 15KW | |||
415/440V | 4KW | 5.5KW | 9KW | 11KW | 15KW | |||
500V | 5.5KW | 7.5KW | 10KW | 15KW | 18.5KW | |||
660/690V | 5.5KW | 7.5KW | 10KW | 15KW | 18.5KW | |||
1000V | – | – | – | – | – | |||
Auxiliary contacts |
range comprising up to 4 N/C or N/O instantaneous,up to 1N/O+1N/C time delay and up to 2 N/O or N/C protected contacts and 2 screen continuity terminals |
|||||||
Compatible manual or auto thermal overload relays |
Class 10 A | 0.10…10A | 0.10…13A | 0.10…18A | 0.10…32A | 0.10…38A | ||
Class 20 | 2.5…10A | 2.5…13A | 2.5…18A | 2.5…32A | – | |||
Suppressor modules (d.c.and low consumption contactors have built-in suppression limiting diode as standard) |
Varistor | ● | ● | ● | ● | ● | ● | ● |
Diode | - | - | ● | - | - | ● | - | |
RC circuit | ● | ● | ● | ● | ● | ● | ● | |
Bidirectional peak | ● | ● | ● | ● | ● | ● | ● | |
Interfaces | Relay | ● | ● | ● | ● | ● | ● | ● |
Relay+override function | ● | ● | ● | ● | ● | ● | ● | |
Solid state | ● | ● | ● | ● | ● | ● | ● | |
Contactor type references | ~ or…3P | CJX2-09N | CJX2-12N | CJX2-18N | CJX2-25N | CJX2-32N | ||
~ 4 - P | – | CJX2-12N | – | CJX2-25N | – | |||
…4P | – | CJX2-12N | – | CJX2-25N | – | |||
Reversing contactor type references |
~ 3P | CJX2-09N | CJX2-12N | CJX2-18N | CJX2-25N | CJX2-32N | ||
…3P | CJX2-09N | CJX2-12N | CJX2-18N | CJX2-25N | CJX2-32N | |||
~ 4P | – | CJX2-12N | – | CJX2-25N | – | |||
…4P | – | CJX2-12N | – | CJX2-25N | – |
Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 660 |
50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 | S5 | Y5 |
60Hz | B6 | D6 | E6 | F6 | M6 | – | U6 | Q6 | – | – | R6 | – | – |
50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 | – | – |
Rated current | le max AC-3 (Ue≤440V) | 38A | 40A | 50A | 65A | 80A | 95A | 115A | 150A | |||||
le AC-1 (0≤60°C) | 60A | 80A | 125A | 200A | ||||||||||
Number of poles | 3 | 4 | 3 | 3 | 4 | 3 | 4 | 3 | 3 | 4 | 3 | |||
Rated operational power in AC-3 |
220/240V | 9KW | 11KW | 15KW | 18.5KW | 22KW | 25KW | 30KW | 40KW | |||||
380/400V | 18.5KW | 18.5KW | 22KW | 30KW | 37KW | 45KW | 55KW | 75KW | ||||||
415/440V | 18.5KW | 22KW | 25/30KW | 37KW | 45KW | 45KW | 59KW | 80KW | ||||||
500V | 18.5KW | 22KW | 30KW | 37KW | 55KW | 55KW | 75KW | 90KW | ||||||
660/690V | 18.5KW | 30KW | 33KW | 37KW | 45KW | 45KW | 80KW | 100KW | ||||||
1000V | – | 22KW | 30KW | 37KW | 45KW | 45KW | 75KW | 90KW | ||||||
Auxiliary contacts |
range comprising up to 4 N/C or N/O instantaneous,up to 1N/O+1N/C time delay and up to 2 N/O or N/C protected contacts and 2 screen continuity terminals |
|||||||||||||
Compatible manual or auto thermal overload relays |
Class 10 A | 0.10…38A | 17…50A | 17…70A | 17…80A | 17…104A | 17…104A | 60…150A | 60…150A | |||||
Class 20 | 17…40A | 17…65A | 17…70A | 17…80A | 60…150A | 60…150A | ||||||||
Suppressor modules (d.c.and low consumption contactors have built-in suppression limiting diode as standard) |
Varistor | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
Diode | - | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | ||
RC circuit | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
Bidirectional peak | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | ||
Interfaces | Relay | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
Relay+override function | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Solid state | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
Contactor type references | ~ or…3P | CJX2-38N | CJX2-40N | CJX2-50N | CJX2-65N | CJX2-80N | CJX2-95N | CJX2-115N | CJX2-150N | |||||
~ 4 - P | – | CJX2-40N | – | CJX2-65N | CJX2-80N | – | CJX2-115N | – | ||||||
…4P | – | CJX2-40N | – | CJX2-65N | CJX2-80N | – | CJX2-115N | – | ||||||
Reversing contactor type references |
~ 3P | CJX2-38N | CJX2-40N | CJX2-50N | CJX2-65N | CJX2-80N | CJX2-95N | CJX2-115N | CJX2-150N | |||||
…3P | CJX2-38N | – | – | – | – | – | – | – | ||||||
~ 4P | – | CJX2-40N | – | CJX2-65N | CJX2-80N | – | CJX2-115N | – | ||||||
…4P | – | – | – | – | – | – | – | – |